Configuring Your Server 4-35
IMPORTANT: Note the following for the rebuild:
The HDD used for rebuild should have the same capacity, rotation
speed, and standard as the defected HDD.
During rebuild, the processing rate is decreased due to much load.
During rebuild, do not shutdown or reboot the server. If the server is
shutdown by an unforeseen accident such as power interruption,
turn on the power again as soon as possible. The rebuild is
automatically restarted.
The interval from the removal of the defected HDD to the
installation of a substitute HDD should be 60 sec or longer.
If the hot-swap rebuild does not operate, perform the manual
rebuild.
Patrol Read
The Patrol Read gives the read & verify test in the entire area of HDDs. It can be performed for all
HDDs assigned to virtual disks and hot-spare disks.
The Patrol Read allows subsequent defects of HDDs to be detected and repaired.
For HDDs configuring redundant virtual disks or those assigned to hot-spare disks, error sectors
detected during Patrol Read can be repaired.
IMPORTANT: Note the following for the patrol read:
Patrol Read feature is factory-set to "Enabled".
To utilize Patrol Read, Universal RAID Utility must be installed.
If the system is restarted, Patrol Read is aborted. After restart of the
system, Patrol Read runs from the first step (top of HDD).