8-28 Troubleshooting
Description
On-screen
message
Recommended action
DIMMG 7 Unc Err
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 13/14 (DIMM Group #7). (in memory mirroring
configuration)
DIMMG 8 Unc Err Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 15/16 (DIMM Group #8). (in memory mirroring
configuration)
Mirror B1 Fail
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 01/02, 05/06, 09/10, or 13/14 (in memory mirroring
configuration).
Mirror B2 Fail Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 03/04, 07/08, 11/12, or 15/16 (in memory mirroring
configuration).
Mirror FailOver
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM (in memory mirroring configuration).
Issue an OS command to reset the CPU blade, though you may continue
use or run the system.
You may continue use or run the system.
1. Check installation status of the failed DIMM Group.
2. Replace the failed DIMM Group.
If the same error persists, contact your service representative.
MEZ 1 C Err A correctable error frequently occurred on mezzanine card in mezzanine
card slot 1.
MEZ 2 C Err A correctable error frequently occurred on mezzanine card in mezzanine
card slot 2.
MEZ 3 C Err A correctable error frequently occurred on mezzanine card in mezzanine
card slot 3.
MEZ 4 C Err A correctable error frequently occurred on mezzanine card in mezzanine
card slot 4.
Issue an OS command to reset the CPU blade, though you may continue
use or run the system.
You may continue use or run the system.
1. Check installation status of the failed mezzanine card.
2. Replace the failed mezzanine card.
If the same error persists, contact your service representative.
SB C Err1
SB C Err2
A correctable error frequently occurred on SAS unit.
Issue an OS command to reset the CPU blade, though you may continue
use or run the system.
You may continue use or run the system.
1. Check connection of signal cable between the CPU unit and the SAS
unit.
2. Check installation status of DIMMs on SAS unit.
If the same error persists, contact your service representative.
PCIE C ErrX
Chipset C Err X
A correctable error frequently occurred on CPU unit.
Issue an OS command to reset the CPU blade, though you may continue
use or run the system.
Replace the CPU blade, though you may continue use or run the system.
If the same error persists, contact your service representative.