Troubleshooting 8-35
Description
On-screen
message
Recommended action
FSB VTT Alm09 FSB VTT voltage alarm (upper limit) occurred.
FSB VTT Alm02 FSB VTT voltage alarm (lower limit) occurred.
B1 FBD VTT Alm09 DIMM VTT voltage alarm (upper limit) occurred.
B1 FBD VTT Alm02 DIMM VTT voltage alarm (lower limit) occurred.
B2 FBD VTT Alm09 DIMM VTT voltage alarm (upper limit) occurred.
B2 FBD VTT Alm02 DIMM VTT voltage alarm (lower limit) occurred.
B1 FBD VCC Alm09 DIMM VCC voltage alarm (upper limit) occurred.
B1 FBD VCC Alm02 DIMM VCC voltage alarm (lower limit) occurred.
B2 FBD VCC Alm09 DIMM VCC voltage alarm (upper limit) occurred.
B2 FBD VCC Alm02 DIMM VCC voltage alarm (lower limit) occurred.
B1 FBD VDD Alm09 DIMM VDD voltage alarm (upper limit) occurred.
B1 FBD VDD Alm02 DIMM VDD voltage alarm (lower limit) occurred.
B2 FBD VDD Alm09 DIMM VDD voltage alarm (upper limit) occurred.
B2 FBD VDD Alm02 DIMM VDD voltage alarm (lower limit) occurred.
BB +1.5v Alm09 +1.5V voltage alarm (upper limit) occurred.
BB +1.5v Alm02 +1.5V voltage alarm (lower limit) occurred.
BB +3.3v Alm09 +3.3V voltage alarm (upper limit) occurred.
BB +3.3v Alm02 +3.3V voltage alarm (lower limit) occurred.
BB +5v Alm09 +5V voltage alarm (upper limit) occurred.
BB +5v Alm02 +5V voltage alarm (lower limit) occurred.
BB +1.2vs Alm09 +1.2VS voltage alarm (upper limit) occurred.
BB +1.2vs Alm02 +1.2VS voltage alarm (lower limit) occurred.
BB +1.25vs Alm09 +1.25VS voltage alarm (upper limit) occurred.
BB +1.25vs Alm02 +1.25VS voltage alarm (lower limit) occurred.
BB +1.5vs Alm09 +1.5VS voltage alarm (upper limit) occurred.
BB +1.5vs Alm02 +1.5VS voltage alarm (lower limit) occurred.
BB +3.3vs Alm09 +3.3VS voltage alarm (upper limit) occurred.
BB +3.3vs Alm02 +3.3VS voltage alarm (lower limit) occurred.
BB +5vs Alm09 +5VS voltage alarm (upper limit) occurred.
BB +5vs Alm02 +5VS voltage alarm (lower limit) occurred.
BB +12vs Alm09 +12VS voltage alarm (upper limit) occurred.
BB +12vs Alm02 +12VS voltage alarm (lower limit) occurred.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Power off the CPU blade by issuring an OS command or press the POWER
switch. Take the CPU blade out of the Blade Enclosure, and install it again.
Then, press the POWER switch to turn on the CPU blade.
Replace the CPU blade.
If the same error persists, contact your service representative.