NEC SigmaBlade B140a-T Guía de usuario Pagina 225

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 376
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 224
Troubleshooting 8-29
Description
On-screen
message
Recommended action
FBD CH1 C Err
A correctable error frequently occurred on DIMM in DIMM socket 01, 05, 09,
or 13.
FBD CH2 C Err
A correctable error frequently occurred on DIMM in DIMM socket 02, 06, 10,
or 14.
Issue an OS command to reset the CPU blade, though you may continue
use or run the system.
You may continue use or run the system.
1. Check installation status of DIMMs in DIMM Group#1, 3, 5, or 7.
2. Replace the DIMMs in failed DIMM Group #1, 3, 5, or 7.
Replace the CPU blade.
If the same error persists, contact your service representative.
FBD CH3 C Err A correctable error frequently occurred on DIMM in DIMM socket 03, 07, 11,
or 15.
FBD CH4 C Err A correctable error frequently occurred on DIMM in DIMM socket 04, 08, 12,
or 16.
Issue an OS command to reset the CPU blade, though you may continue
use or run the system.
You may continue use or run the system.
1. Check installation status of DIMMs in DIMM Group#2, 4, 6, or 8.
2. Replace the DIMMs in failed DIMM Group #2, 4, 6, or 8.
Replace the CPU blade.
If the same error persists, contact your service representative.
Relation of DIMM Group / DIMM number / Channel number
DIMM Group number DIMM number Channel number
01 11
02 2
03 32
04 4
05 13
06 2
07 34
08 4
09 15
10 2
11 36
12 4
13 17
14 2
15 38
16 4
Vista de pagina 224
1 2 ... 220 221 222 223 224 225 226 227 228 229 230 ... 375 376

Comentarios a estos manuales

Sin comentarios