Troubleshooting 8-27
When STATUS lamp is flashing in amber
DescriptionOn-screen
message
Recommended action
CPU Reconfigured The system has started with processor degraded.
Try the following steps to cancel the error.
Run BIOS SETUP, select [Main] - [Processor Settings] - [Processor Retest]-
[Yes], then select [Exit] - [Exit Saving Changes].
If the same error persists, contact your service representative.
Mem Reconfigured The system has started with memory degraded.
Try the following steps to cancel the error.
Run BIOS SETUP, select [Advanced] - [Memory Configuration] - [Memory
Retest]- [Yes], then select [Exit] - [Exit Saving Changes].
If the same error persists, contact your service representative.
DIMM 1 C Err A correctable error frequently occurred on DIMM in DIMM socket 01.
DIMM 2 C Err A correctable error frequently occurred on DIMM in DIMM socket 02.
DIMM 3 C Err A correctable error frequently occurred on DIMM in DIMM socket 03.
DIMM 4 C Err A correctable error frequently occurred on DIMM in DIMM socket 04.
DIMM 5 C Err A correctable error frequently occurred on DIMM in DIMM socket 05.
DIMM 6 C Err A correctable error frequently occurred on DIMM in DIMM socket 06.
DIMM 7 C Err A correctable error frequently occurred on DIMM in DIMM socket 07.
DIMM 8 C Err A correctable error frequently occurred on DIMM in DIMM socket 08.
DIMM 9 C Err A correctable error frequently occurred on DIMM in DIMM socket 09.
DIMM 10 C Err A correctable error frequently occurred on DIMM in DIMM socket 10.
DIMM 11 C Err A correctable error frequently occurred on DIMM in DIMM socket 11.
DIMM 12 C Err A correctable error frequently occurred on DIMM in DIMM socket 12.
DIMM 13 C Err A correctable error frequently occurred on DIMM in DIMM socket 13.
DIMM 14 C Err A correctable error frequently occurred on DIMM in DIMM socket 14.
DIMM 15 C Err A correctable error frequently occurred on DIMM in DIMM socket 15.
DIMM 16 C Err A correctable error frequently occurred on DIMM in DIMM socket 16.
Sparing FailOver
A correctable error frequently occurred on DIMM, and the online spare
memory is failed over (in online spare memory configuration).
DIMMG 1 Unc Err
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 01/02 (DIMM Group #1). (in memory mirroring
configuration)
DIMMG 2 Unc Err Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 03/04 (DIMM Group #2). (in memory mirroring
configuration)
DIMMG 3 Unc Err
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 05/06 (DIMM Group #3). (in memory mirroring
configuration)
DIMMG 4 Unc Err Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 07/08 (DIMM Group #4). (in memory mirroring
configuration)
DIMMG 5 Unc Err
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 09/10 (DIMM Group #5). (in memory mirroring
configuration)
DIMMG 6 Unc Err Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in DIMM socket 11/12 (DIMM Group #6). (in memory mirroring
configuration)
Comentarios a estos manuales