8-18 Troubleshooting
On-screen error message Recommended action
8450 Can't Read FRU on
Mezzanine Slot 1
8451 Can't Read FRU on
Mezzanine Slot 2
8452 Can't Read FRU on
Mezzanine Slot 3
8453 Can't Read FRU on
Mezzanine Slot 4
1. Take one of the following measures to reboot (reset) the CPU
blade.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
2. Take one of the following measures to power off the CPU
blade and then on.
* Power off the CPU blade from OS, then press the POWER
switch to power on.
* Press the POWER switch to power off the CPU blade, then
press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
3. Power off the CPU blade by issuring an OS command or
press the POWER switch. Take the CPU blade out of the
Blade Enclosure, and install it again. Then, press the POWER
switch to turn on the CPU blade.
4. Check installation status of failed mezzanine card.
5. Replace the failed mezzanine card.
6. Replace the CPU blade.
7. If the same error persists, contact your service representative.
Resource conflict 1. Take one of the following measures to reboot (reset) the CPU
blade.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
2. Check installation status of mezzanine card.
3. Replace the mezzanine card.
4. Replace the CPU blade.
5. If the same error persists, contact your service representative.
Expansion Rom not
initialize
1. Run BIOS SETUP. Select [Advanced] - [PCI Configuration] or
[Advanced] - [PCI Configuration] - [Onboard NIC] and change
[Option ROM Scan] to [Disabled] for the device of which use
frequency of option ROM is low. Then, select [Exit] - [Exit
SavingChanges].
2. Take one of the following measures to reboot (reset) the CPU
blade.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
3. Check installation status of mezzanine card.
4. Replace the mezzanine card.
5. Replace the CPU blade.
6. If the same error persists, contact your service representative.
Comentarios a estos manuales