4-2 Configuring Your Server
Starting SETUP Utility
Powering on the CPU blade starts POST (Power On Self-Test) and displays its check results. If the
NEC logo is displayed, press Esc.
After a while, the following message appears at bottom left on the screen.
Pattern 1:
Press <F2> to enter SETUP
Pattern 2:
Press <F2> to enter SETUP or <F12> to Network
Pattern 3:
Press <F1> to resume, <F2> to enter Setup, <F12> to Network
* The message depending on the status of CPU blade.
Press F2 to start the SETUP utility and display its Main menu.
If you have previously set a password with the SETUP utility, the password entry screen appears.
Enter the password.
Enter password:[ ]
Up to three password entries will be accepted. If you fail to enter the password correctly for three
consecutive times, the CPU blade halts. (You can no longer proceed.) Power off the CPU Blade.
NOTE: The CPU blade is provided with two levels of password:
Supervisor and User. With the Supervisor password, you can view and
change all system parameters. With the User password, system
parameters available for viewing and changing are limited.