Troubleshooting 8-23
Description
On-screen
message
Recommended action
BIOSRecovery run A fatal error occured on system BIOS ROM.
Take one of the following measures to reboot (reset) the CPU blade.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Replace the CPU blade.
Contact your service representative.
DIMMG 1 Unc Err An uncorrectable error occured on DIMM in DIMM socket 01/02 (DIMM
Group #1).
DIMMG 2 Unc Err An uncorrectable error occured on DIMM in DIMM socket 03/04 (DIMM
Group #2).
DIMMG 3 Unc Err An uncorrectable error occured on DIMM in DIMM socket 05/06 (DIMM
Group #3).
DIMMG 4 Unc Err An uncorrectable error occured on DIMM in DIMM socket 07/08 (DIMM
Group #4).
DIMMG 5 Unc Err An uncorrectable error occured on DIMM in DIMM socket 09/10 (DIMM
Group #5).
DIMMG 6 Unc Err An uncorrectable error occured on DIMM in DIMM socket 11/12 (DIMM
Group #6).
DIMMG 7 Unc Err An uncorrectable error occured on DIMM in DIMM socket 13/14 (DIMM
Group #7).
DIMMG 8 Unc Err An uncorrectable error occured on DIMM in DIMM socket 15/16 (DIMM
Group #8).
Take one of the following measures to reboot (reset) the CPU blade.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
1. Check installation status of failed DIMM Group.
2. Replace the failed DIMM Group.
Replace the CPU blade.
If the same error persists, contact your service representative.