Troubleshooting 8-5
On-screen error message Recommended action
0B50 Processor #1 with error
taken offline
0B51 Processor #2 with error
taken offline
0B52 Processor #3 with error
taken offline
0B53 Processor #4 with error
taken offline
1. Run BIOS SETUP, select [Main] - [Processor Settings] -
[Processor Retest] - [Yes], then select [Exit] - [Exit Saving
Changes].
2. Replace the failed CPU.
3. Replace the CPU blade.
4. If the same error persists, contact your service representative.
Note: The detailed error information can be obtained by viewing
the IPMI system event log.
If the CPU has been replaced, run BIOS SETUP and
restarting the CPU blade, select [Main] - [Processor
Settings] - [Processor Retest] - [Yes], then select [Exit] -
[Exit Saving Changes].
0B5F Forced to use Processor
with error
1. Run BIOS SETUP, select [Main] - [Processor Settings] -
[Processor Retest] - [Yes], then select [Exit] - [Exit Saving
Changes].
2. Check installation status of DIMMs.
3. Check connection status of signal cable between the CPU
unit and the SAS unit.
4. Check installation status of DIMMs on SAS unit.
5. Check installation status of mezzanine card.
6. Replace the CPU blade.
7. Replace the mezzanine card.
8. Replace the DIMMs.
9. If the same error persists, contact your service representative.
Note: The detailed error information can be obtained by viewing
the IPMI system event log.
If the CPU has been replaced, run BIOS SETUP and
restarting the CPU blade, select [Main] - [Processor
Settings] - [Processor Retest] - [Yes], then select [Exit] -
[Exit Saving Changes].
0B60 DIMM group #1 has been
disabled
0B61 DIMM group #2 has been
disabled
0B62 DIMM group #3 has been
disabled
0B63 DIMM group #4 has been
disabled
0B64 DIMM group #5 has been
disabled
0B65 DIMM group #6 has been
disabled
0B66 DIMM group #7 has been
disabled
0B67 DIMM group #8 has been
disabled
1. Run BIOS SETUP, select [Advanced] - [Memory
Configuration] - [Memory Retest] - [Yes], then select [Exit] -
[Exit Saving Changes].
2. Check installation status of failed DIMMs.
3. Replace the failed DIMMs.
4. Replace the CPU blade.
5. If the same error persists, contact your service representative.
Note: The detailed error information can be obtained by viewing
the IPMI system event log.
If the DIMMs have been replaced, run BIOS SETUP and
restarting the CPU blade, select [Advanced] - [Memory
Configuration] - [Memory Retest] - [Yes], then select [Exit]
- [Exit Saving Changes].
Comentarios a estos manuales