8-30 Troubleshooting
Messages displayed on lower line
When STATUS lamp is flashing in red
Description
On-screen
message
Recommended action
Proc1 IERR An error was detected in CPU #1.
Proc2 IERR An error was detected in CPU #2.
Proc3 IERR An error was detected in CPU #3.
Proc4 IERR An error was detected in CPU #4.
Take one of the following measures to reboot (reset) the CPU blade.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
1. Check installation status of the failed CPU.
2. Check installation status of heat sink on the failed CPU.
3. Replace the failed CPU.
Replace the CPU blade.
If the same error persists, contact your service representative.
Proc1ThermalTrip Forced power-off occurred due to a thermal error in CPU #1.
Proc2ThermalTrip Forced power-off occurred due to a thermal error in CPU #2.
Proc3ThermalTrip Forced power-off occurred due to a thermal error in CPU #3.
Proc4ThermalTrip Forced power-off occurred due to a thermal error in CPU #4.
Take one of the following measures to power on the CPU blade.
* Press the POWER switch to power on the CPU blade.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
1. Check if fans in Blade Enclosure work normally.
2. Refer to the User’s Guide of the Blade Enclosure to make sure that the
sufficient number of fans are installed in correct locations.
3. Check if the fans and CPU blades are installed in correct locations.
4. Check installation status of heat sink of the CPU blade.
5. Check if the ambient temperature of installation location satisfies the
operation guarantee condition.
1. Check installation status of the failed CPU.
2. Check installation status of heat sink on the failed CPU.
3. Replace the failed CPU.
Replace the CPU blade.
If the same error persists, contact your service representative.