Upgrading Your Server 9-17
6. Open the levers at both ends of the DIMM socket.
7. Push the DIMM into the socket straight.
IMPORTANT: Use extreme care when installing a DIMM. Applying
too much pressure can damage the socket.
NOTE: Make sure of the orientation of the DIMM. The connecting
side of the DIMM has a cut-out (key slot) to prevent an incorrect
insertion.
If the DIMM is inserted into the DIMM socket, the levers are automatically closed.
8. Close the lever firmly.
9. Install the DIMMs in another DIMM socket according to steps 6 through 8.
10. Install the components having been removed.
11. Make sure that no error message appears on the POST screen.
See Chapter 8 for details of the POST error messages.
If the CPU blade is not started, the DIMM may not be installed on the socket correctly.
Install the DIMM again.
12. Run SETUP and select [Advanced] – [Memory Configuration] to make sure that "DIMM
Group #x Status" (x: DIMM Group number) is set to "Normal" (see Chapter 4).
Key slot
Key