Step 2 After Consistency Check is started, the
progress of the Consistency Check appears on the
Operation View. At the completion of the Consistency
Check, [Status] on the Operation View is changed to
[Completed].
raidcmd
Step 1 Execute "
" command with -op option
and the following parameters.
: Number of the RAID Controller containing the Logical
Drive for which Consistency Check is executed (If specify
"all" as parameter, the targets are all Logical Drives of all
RAID Controllers)
: Number of the Logical Drive for which Consistency
Check is executed (If specify "all" as parameter, the targets are all Logical Drives of RAID Controllers specified by -c)
: Specify "start" to start Consistency Check
To execute Consistency Check for all Logical Drives of a RAID Controller which not support Patrol Read or of which the
Patrol Read is disabled, use "
" command of the raidcmd.
raidcmd ccs
For the RAID Controller which support Patrol Read o
r of which the Patrol Read is enabled,
" command is actually not executed even if you execute it.
Step 2 After the Consistency Check is started, the raidcmd terminates normally. Check the execution status of the
Consistency Check by using "
" command.
Executing Consistency Check Manually (Automatic Stop
Disabled)
You can execute the Consistency Check through entire Logical Drive without stop even if a Medium Error is
detected frequently.
The procedure of starting Consistency Check (Automatic Stop Disabled) is described below.
If you carries out this function at the physical device which media error occurs frequently,
there is a fear that the access performance to this physical device degrades.
When y
ou'd like
to confirm the consistency until the end,
please use this function before replacing the
RAID Viewer
Step 1 Start the RAID Viewer. Click a Logical Drive on
the Tree View. Then click [Start Consistency Check]
->[Automatic Stop Disabled] on the [Control] menu.
Step 2 After Consistency Check is started, the
progress of the Consistency Check appears on the
Operation View. At the completion of the Consistency
Check, [Status] on the Operation View is changed to
[Completed].
> raidcmd cc -c=1 -l=2 -op=start
>
> raidcmd oplist
RAID Controller #1
LD #2 : Consistency Check (Running 30%)
>