NEC ESMPRO Manager
Simultaneous operation from two or more NEC ESMPRO
Manager
The following error might occur from NEC ESMPRO Manager to RAID System when runs the operation. When the
following error occurs, there is a possibility of running the operation at the same time from other NEC ESMPRO
Manager to same RAID System. Please changes timing if whether it operates it like this is confirmed, and it
goes and operate it again.
"The system error occurred. Please ask it which component has broken."
Notes on use of Web GUI
Do not click Back/Forward button on a browser of the Web GUI.
Notes on use of function to Make/Remove Hot Spare by NEC
ESMPRO Manager
You can use this function only NEC ESMPRO Manager Ver. 5.72 or later.
NEC ESMPRO ServerAgentService
Notes on use report coordination with Windows Server 2008
R1 ServerCore
If using NEC ESMPRO Manager Ver 6.0 or later, NEC ESMPRO ServerAgentService is not supporting Windows
Server 2008 R1 ServerCore.
RAID Controller
Notes on updating firmware of the RAID Controller
Do not stop raidsrv service (including restart), abort raidcmd and stop system (including restart) when updating
the firmware of the RAID Controller. If doing these operations during updating firmware of RAID Controller, there is
a possibility that the RAID Controller fail.
Consistency Check
Notes on executing Consistency Check Manually (Automatic
Stop Disabled)
If restarting a system or raidsrv service during executing "Start Consistency Check (Automatic Stop Disabled)",
behavior of Consistency Check changes with kind of RAID Controller you use. See the following table for details.