NEC Express5800/R120f-1M Guía de usuario Pagina 129

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 128
Figure 30 Display of RAID Viewer / raidcmd (Detection of S.M.A.R.T. error)
Tree View of RAID Viewer
The status of the node of Physical Device becomes [Warning] when
S.M.A.R.T. error is detected.
Property of RAID Viewer
The [S.M.A.R.T.] of Physical Device Properties becomes [Detected] when S.M.A.R.T. error is detected.
Become [Warning] by
existence of [Warning] node.
Physical Device which
detected S.M.A.R.T. error
[Warning]
Property of raidcmd
Physical Device which
detected S.M.A.R.T. error
[Detected]
The [S.M.A.R.T.] of Physical Device Properties becomes [Detected] when S.M.A.R.T. error is detected.
> raidcmd property -tg=pd -c=1 -p=e252s4
RAID Controller #1 Physical Device e252s4
Enclosure : 252
Enclosure Position : Internal
Slot : 4
ID : 21
Device Type : HDD
Interface : SAS
Vendor/Model : SEAGATE ST936701SS
Firmware Version : 0003
Serial Number : 3LC05ZZG
Capacity : 33GB
Status : Online
S.M.A.R.T. : Normal
Power Status : On
> raidcmd property -tg=pd -c=1 -p= e252s4
RAID Controller #1 Physical Device e252s4
Enclosure : 252
Enclosure Position : Internal
Slot : 4
ID : 21
Device Type : HDD
Interface : SAS
Vendor/Model : SEAGATE ST936701SS
Firmware Version : 0003
Serial Number : 3LC05ZZG
Capacity : 33GB
Status : Online
S.M.A.R.T. : Detected
Power Status : On
Physical Device which
detected S.M.A.R.T. error
[Detected]
129
Vista de pagina 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 143 144

Comentarios a estos manuales

Sin comentarios