raidcmd
Step 1 Execute raidcmd without command to check the component where a failure occurs.
Step 2 Execute "
sbuzzer
" command with the
following parameter.
-c
: Number of the RAID Controller for which Buzzer is
stopped
Ex. Stop the Buzzer of the RAID Controller (RAID Controller number:1)
raidcmd sbuzzer -c=1
Sending Alert to ESMPRO Manager
Among RAID System events logged in the OS Log, the Universal RAID Utility sends important events which may
affect the operations and managements of the server to the NEC ESMPRO Manager as alerts. To send alerts,
the event monitoring function provided by the NEC ESMPRO Agent or the NEC ESMPRO ServerAgentService can
be used. If the NEC ESMPRO Agent or the NEC ESMPRO ServerAgentService is installed in the server in which
the Universal RAID Utility is installed and alert transmission is set, RAID System events detected by the
Universal RAID Utility will be automatically subject to alert transmission to the NEC ESMPRO Manager.
For alerts sent to the NEC ESMPRO Manager, see " Appendix C : Logs/Events ".
For alert t
ransmission provided by the NEC ESMPRO Agent or the NEC ESMPRO
ServerAgentService
, see the relevant documentation of these software.
If using the NEC ESMPRO Manager earlier than Ver6.0, you should use NEC ESMPRO Agent.
If using the NEC ESMPRO Manager Ver6.
0 or later, you should use NEC ESMPRO
SeverAgentSetvice.
If
OS of the server in which Universal RAID Utility is being installed is Linux or VMware ESX,
please use
NEC ESMPRO Agent in spite of the version of NEC ESMPRO Manager.
Using report coordination of NEC ESMPRO/AlertManager
To use alerts on report coordination of the NEC ESMPRO/AlertManager, add the following registry to the
computer in which the NEC ESMPRO Manager is installed.
If the registry has existed already, you do not need to correct the registry additionally.
Registry key
CPU architecture (x86) :
HKEY_LOCAL_MACHINE\SOFTWARE\NEC\NVBASE\AlertViewer\AlertType\URAIDUTL
CPU architecture (x64) :
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\NEC\NVBASE\AlertViewer\AlertType\URAIDUTL
Values
Name
Type
Data
WavDefault
REG_SZ
Default.wav
AniDefault REG_SZ Default.bmp
Image REG_SZ Default.bmp
SmallImage REG_SZ Default.bmp
Permission
In case of the operation system where ESMPRO Manager is installed is Windows XP (exclude Home Edition),
add the following permissions.
Name
Type
Administrators Full Control
> raidcmd sbuzzer -c=1
>