NEC Express5800/R120f-1M Guía de usuario Pagina 88

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 87
Step 4 Click [Next]. The [Check the contents, and
completing the "Create SSD Cache Drive" Wizard]
window appears.
The window shows the contents of SSD Cache Drive to
be created.
To create an SSD Cache Drive with the settings
displayed, click [Finish]. To change the settings , click
[Back].
Click [Finish] to create an SSD Cache Drive and close
the wizard. After the wizard closes, see the Tree View
to check the contents.
Click [Back] to cancel the creation of SSD Cache Drive.
raidcmd
Step 1 Connect Solid State Drive(s) used for an SSD Cache Drive to the RAID Controller before executing raidcmd if
required.
Step 2 Execute "
mkscd
" command with following
parameters.
-c
: Number of RAID Controller in which an SSD Cache
Drive is created.
-p
: Numbers of the Physical Device(s) used for creating of
SSD Cache Drive.
Ex) Create SSD Cache Drive using the Solid State
Drives (RAID Controller Number is 1, Physical Device
Number is e252s6, e252s7).
raidcmd mkscd -c=1 -p= e252s6,e252s7
Step 3 Display the confirmation message. Type "yes" to create an SSD Cache Drive. Type "no" to cancel the creation
of SSD Cache Drive.
Step 4 raidcmd terminates normally when SSD Cache Drive is created successfully. You can check the property of
the created SSD Cache Drive by using "property" command.
> raidcmd mkscd c=1 p=e252s6,e252s7
raidcmd creates SSD Cache Drive #2
Do you continue ? [yes(y) or no(n)] : yes
raidcmd created SSD Cache Drive #2.
>