NEC ESMPRO Manager Setup Guide
81
Chapter4 EM Card and Chassis Management
4.1 Overview
The NEC ESMPRO Manager has following functions by communication with the EM card in a blade
enclosure,
Information Collection
NEC ESMPRO Manager collects the status and the information of the blade enclosure as follows.
-- Blade / EM Card / Switch Module List
If the slot state of CPU blade, EM card or switch module is changed, NEC ESMPRO Manager
collects current slot state.
-- Chassis Information
NEC ESMPRO Manager collects the blade enclosure name, the name and ID of the rack in which
the blade enclosure is installed.
-- EM Card / Switch Module Status
NEC ESMPRO Manager obtains the STATUS Lamp of the EM card and the switch module.
Component Monitoring
NEC ESMPRO Manager always monitors the slot state in the blade enclosure and the STATUS Lamp of
the EM card and the Switch Module. When some slot state change or failure occurs, NEC ESMPRO
Manager notifies the operator.
CPU Blade Auto Setting
When NEC ESMPRO Manager detects new CPU blade installed on the blade enclosure, the NEC
ESMPRO Manager configures BMC on the CPU blade (managed component) through the EM card to
control the managed component remotely. NEC ESMPRO Manager also registers the managed
component for its own, and execute the "Check Connection".
4.2 System Requirements
NEC ESMPRO Manager can manage the following EM card.
Hardware
EM card that is listed "Appendix D. Managed Components Summary".
Communication Medium
TCP/IP network
CHECK:
・NEC ESMPRO Agent Extension and NEC DianaScope Agent cannot be installed on
EM card.