NEC Express5800/R110f-1E Guia de preparacion Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 125
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
NEC ESMPRO Manager Setup Guide
20
CHECK:
If a managed component supports SOL and "Redirection" is selected to "Enable", you
must change the following items necessary for the remote console via the LAN.
Input <F2> key on the POST screen of the managed component.
"SETUP" page – "Advanced" page – "Serial Port Configuration" page – "Flow
Control": Hardware RTS/CTS.
Select "OK".
The configuration information is set in the BMC.
Select network configuration screen.
In the case of BMC Configuration: “BMC Configuration” “Network” “Property”
In the case of Server Configuration Utility: “EXPRESSSCOPE Engine 3” “Configuration”
“Network” “IPv4 Property”
CHECK:
If you configure a fault tolerant server, there are the menu ”Network: CPU/IO module
0” and the menu “Network 1: CPU/IO module 1”. Please configure both CPU/IO
modules.
Set the following items. The other items can be used with the default values.
-- "DHCP"
Determine whether to dynamically obtain an IP address from a DHCP server.
If the item is set Enable and applied, BMC set the value obtained from DHCP server on "IP Address",
"Subnet Mask" and "Default Gateway".
-- "IP Address"
Enter the BMC IP address.
-- "Subnet Mask"
Enter the subnet mask for the IP address.
-- "Default Gateway"
Enter the default gateway if the managed component connects to management PC via any gateway.
The following screen shows example.
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 124 125

Comentarios a estos manuales

Sin comentarios