NEC Express5800/R110f-1E Guia de preparacion Pagina 68

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 125
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 67
NEC ESMPRO Manager Setup Guide
67
If the managed component is a server which has EXPRESSSCOPE
Engine SP3(2BMC model), you should enter the IP address of the
management LAN port for the Standby BMC to the form.
Subnet Mask1 Enter the subnet mask that is specified on LAN2 of the BMC
configuration for the managed component.
If the managed component is a fault tolerant server, you should enter the
subnet mask of the management LAN port for the CPU/IO module 1 to
the form.
If the managed component is a server which has EXPRESSSCOPE
Engine SP3(2BMC model), you should enter the subnet mask of the
management LAN port for the Standby BMC to the form.
CHECK:
*1 If NEC ESMPRO Manager is installed on Linux system, “SNMP” is not supported.
CHECK:
*2 If a self signed certificate is installed on the managed server for HTTPS
communication, a setting to allow it is required. Refer to “1.1 Setup Flow” for
detailed information.
CHECK:
*3 On “Environment” – “Auto Registration Setting List” screen, you can manage a list
of username/password and authentication key. All entries in the list are used for
auto registration every time.
The following screen shows an example.
Vista de pagina 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 124 125

Comentarios a estos manuales

Sin comentarios