96
Monitoring Battery Status
The Universal RAID Utility can monitor Battery status which the RAID Controller detects by the following means.
raidcmd
RAID Log Buzzer OS Log Alert
Depending on type of
RAID Controller
The Universal RAID Utility monitors events of the Battery installed in the RAID Controller. The Universal RAID Utility logs
detected Battery events in the RAID Log. Any event indicating occurrence of a problem in the Battery reflects to the
[Status] of Battery on RAID Viewer and the [Battery Status] of RAID Controller on raidcmd (changes the status to
[Warning]). The Battery status is retailed until the problem is solved.
Figure 26 Display of RAID Viewer / raidcmd (Abnormal Battery operation)
> raidcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
Vendor : LSI Logic
Model : MegaRAID SAS PCI
Express(TM) ROMB
Firmware Version : 1.14-02-0342
Cache Size : 128MB
Battery Status : Normal
Initialize Priority : Middle
Rebuild Priority : High
Consistency Check Priority : High
The status of the node of Battery becomes [Warning] when there are
problem in Battery.
The [Status] of Battery Properties becomes [Warning] when there are problem in Battery.
Become [Warning] by existence
of [Warning] node.
[Warning]
[Warning]
> raidcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
Vendor : LSI Logic
Model : MegaRAID SAS PCI
Express(TM) ROMB
Firmware Version : 1.14-02-0342
Cache Size : 128MB
Battery Status : Warning
Initialize Priority : Middle
Rebuild Priority : High
Consistency Check Priority : High
[Warning]
The [Battery Status] of RAID Controller Properties becomes [Warning] when there are problem in Battery.