About the start when Runtime component of Microsoft
Visual C++ 2005 SP1 library does not exist
RAID Viewer fails in the start if it doesn't install Runtime component of Microsoft Visual C++ 2005 SP1 library.
1. When Runtime component of Microsoft Visual C++ 2005 SP1 library does not exist
The message dialog to show the occurrence of the problem is displayed, because the DLL of Runtime
component of Microsoft Visual C++ 2005 SP1 library cannot be loaded.
And, the following events are registered in the event log of OS.
SideBySide 32 Dependent Assembly Microsoft.VC80.CRT could not be found and Last Error
was The referenced assembly is not installed on your system.
SideBySide 59 Resolve Partial Assembly failed for Microsoft.VC.80.CRT. Reference error
message: The referenced assembly is not installed on your system.
SideBySide 59 Generate Activation Context for (installation folder of Universal RAID
Utility)\gui\bridge.dll. Reference error message: The operation completed
successfully.
You must install Runtime component of Microsoft Visual C++ 2005 SP1 library to use the RAID Viewer.
NEC ESMPRO Manager
Simultaneous operation from two or more NEC ESMPRO
Manager
The following error might occur from NEC ESMPRO Manager to RAID System when runs the operation. When the
following error occurs, there is a possibility of running the operation at the same time from other NEC ESMPRO
Manager to same RAID System. Please changes timing if whether it operates it like this is confirmed, and it goes
and operate it again.
"The system error occurred. Please ask it which component has broken."