NEC Express5800/R110d-1E Guía de usuario Pagina 87

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 106
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 86
87
raidcmd
Use "stspd" command.
Step 1 Execute "stspd" command with -st option
and the following parameters.
-c : Number of the RAID Controller containing the Physical
Device with its status set to [Failed] forcibly
-p : Number of the Physical Device with its status set to
[Failed] forcibly
-st : Specify "offline"
Step 2 Displays the Warning message and the
confirmation message. Type "yes" to reply to the
confirmation message. Then [Status] of the Physical
Device is changed to [Failed]. Type "No" to abort the
change status of the Physical Drive.
Step 3 If "stspd" command succeeds, the
[Status] of the Physical Device is set to [Failed].
> raidcmd stspd -c=1 -p=1 -st=offline
Make the Physical Device offline.
[Warning] The redundancy of Logical Drive will be lost.
Do you continue ? [yes(y) or no(n)] : yes
Change the status of Physical Device #3 to "Offline"
>
> raidcmd property -tg=pd -c=1 -p=3
RAID Controller #1 Physical Device #3
ID : 2
Enclosure : 1
Slot : 3
Device Type : HDD
Interface : SAS
Vendor/Model : SEAGATE ST936751SS
Firmware Version : 0001
Serial Number : 3PE073VM
Capacity : 33GB
Status : Failed
S.M.A.R.T. : Normal
>
1