raidcmd
Use "hotspare" command.
Step 1 Execute "hotspare" command with -mr
option and the following parameters.
-c : Number of the RAID Controller containing the Physical
Device with which a Hot Spare is made
-p : Number of the Physical Device with which a Dedicated
Hot Spare is made(The capacity of the Physical Device
should be equal to or larger than any Physical Device
used by the target Disk Array)
-mr : Specify "make" to make Dedicated Hot Spare
-a : Number of the target Disk Array using the Dedicated
Hot Spare
Step 2 If you see the property of the Physical
Device after making the Dedicated Hot Spare, you
find that the value of [Status] is changed to [Hot
Spare] and new item [Hot Spare Information] appears
with value [Dedicated].
Removing Hot Spare
The procedure of removing a Hot Spare is described below.
RAID Viewer
Use [Remove Hot Spare] in [Control] menu.
Step 1
Start the RAID Viewer. Click a Physical Device with [Status] being [Hot Spare] on the Tree View.
Step 2 Select [Hot Spare] on the pull-down
menu of menu item [Control] and click [Remove Hot
Spare].
Step 3 If you see the property of the Physical
Device after removing it from the Hot Spare, you can
find that the value of [Status] is set to [Ready] and
item [Hot Spare Information] disappears.
raidcmd
Use "hotspare" command.
Step 1 Execute "hotspare" command with -mr
option and the following parameters.
-c : Number of the RAID Controller containing the Physical
Device from which the Hot Spare is removed
-p : Number of the Physical Device from which the Hot
Spare is removed
-mr : Specify "remove" to remove Hot Spare
Step 2 If you see the property of the Physical
Device after removing the Hot Spare, the value of
[Status] is changed to [Ready] and item [Hot Spare
Information] disappears.
> raidcmd hotspare -c=1 -p=6 -mr=make -a=2
Make Dedicated Hot Spare.
Do you continue ? [yes(y) or no(n)] : yes
>
> raidcmd property -tg=pd -c=1 -p=6
RAID Controller #1 Physical Device #6
ID : 5
Enclosure : 1
Slot : 6
Device Type : HDD
Interface : SAS
Vendor/Model : Seagate ST12345678
Firmware Version : BK09
Serial Number : 1111
Capacity : 146GB
Status : Hot Spare
Hot Spare Information : Dedicated (Disk Array #2)
S.M.A.R.T. : Normal
>
1
2
> raidcmd hotspare -c=1 -p=6 -mr=remove
Remove Hot Spare.
Do you continue ? [yes(y) or no(n)] : yes
>
> raidcmd property -tg=pd -c=1 -p=6
RAID Controller #1 Physical Device #6
ID : 5
Enclosure : 1
Slot : 6
Device Type : HDD
Interface : SAS
Vendor/Model : Seagate ST12345678
Firmware Version : BK09
Serial Number : 1111
Capacity : 146GB
Status : Ready
S.M.A.R.T. : Normal
>