95
Operation when the Logical Drive is offline due to failure of Physical Device
If you continue to use the RAID System with lost redundancy of a Logical Drive and another Physical Device is failed further, the redundancy of the Logical Drive is lost completely
(two or more Physical Devices of RAID Level 1 or 5 is failed, three or more Physical Devices of RAID Level 6 is failed). The status of a Logical Drive without redundancy is offline
(with its [Status] being [Offline]). The data in a Logical Drive in the offline status is lost. Replace all failed Physical Devices and Rebuild the RAID System.
Figure 25 Display of RAID Viewer / raidcmd (Under lost redundancy of Logical Drive)
existence of
[Offline] node.
> raidcmd property -tg=ld -c=1 -l=1
RAID Controller #1 Logical Drive #1
ID : 0
Physical Device Number : 1, 2, 3
Disk Array Number : 1
RAID Level : 5
Stripe Size : 64KB
Capacity : 146GB
Cache Mode (Current) : Write Back
Cache Mode (Setting) : Auto Switch
Status : Offline
>
Structure and Status of RAID System
[Offline]
> raidcmd property -tg=pd -c=1 -p=3
RAID Controller #1 Physical Device #3
ID : 2
Enclosure : 1
Slot : 3
Device Type : HDD
Interface : SAS
Vendor/Model : Seagate ST12345678
Firmware Version : BK09
Serial Number : 1111
Capacity : 146GB
Status : Failed
S.M.A.R.T. : Normal
>
[Online]
[Failed]
[Failed]
RAID Level: 5
Devices
[Failed]
> raidcmd property -tg=pd -c=1 -p=3
RAID Controller #1 Physical Device #3
ID : 2
Enclosure : 1
Slot : 3
Device Type : HDD
Interface : SAS
Vendor/Model : Seagate ST12345678
Firmware Version : BK09
Serial Number : 1111
Capacity : 146GB
Status : Failed
S.M.A.R.T. : Normal
>
Comentarios a estos manuales