93
Operation when redundancy of Logical Drive degraded or lost due to failure of Physical Device
If one or more Physical Devices used by a Logical Drive are failed (with their [Status] being [Failed]) to degraded (one Physical Device of RAID Level 6 is failed) or lost (one Physical
Device of RAID Level 1 or 5 is failed, two Physical Devices of RAID Level 6 is failed) the redundancy of the Logical Drive, the Logical Drive is degraded (with its [Status] being
[Degraded]).
Figure 23 Display of RAID Viewer / raidcmd (Lost the redundancy of Logical Drive)
> raidcmd property -tg=pd -c=1 -p=2
RAID Controller #1 Physical Device #2
ID : 0
Enclosure : 1
Slot : 2
Device Type : HDD
Interface : SAS
Vendor/Model : Seagate ST12345678
Firmware Version : BK09
Serial Number : 1111
Capacity : 146GB
Status : Online
S.M.A.R.T. : Normal
>
> raidcmd property -tg=pd -c=1 -p=1
RAID Controller #1 Physical Device #1
ID : 0
Enclosure : 1
Slot : 1
Device Type : HDD
Interface : SAS
Vendor/Model : Seagate ST12345678
Firmware Version : BK09
Serial Number : 1111
Capacity : 146GB
Status : Online
S.M.A.R.T. : Normal
>
[Hot Spare]
[Failed]
RAID Level: 5
[Online]
[Online]
> raidcmd property -tg=pd -c=1 -p=3
RAID Controller #1 Physical Device #3
ID : 2
Enclosure : 1
Slot : 3
Device Type : HDD
Interface : SAS
Vendor/Model : Seagate ST12345678
Firmware Version : BK09
Serial Number : 1111
Capacity : 146GB
Status : Failed
S.M.A.R.T. : Normal
>
> raidcmd property -tg=ld -c=1 -l=1
RAID Controller #1 Logical Drive #1
ID : 0
Physical Device Number : 1, 2, 3
Disk Array Number : 1
RAID Level : 5
Stripe Size : 64KB
Capacity : 146GB
Cache Mode (Current) : Write Back
Cache Mode (Setting) : Auto Switch
Status : Degraded
>
Structure and Status of RAID System
[Degraded]
existence of
[Failed] node.
Device
[Failed]
Comentarios a estos manuales