3. Setting Up Windows Server 2008 R2
Express5800/R120d-1M, R120d-2M Installation Guide (Windows)
Chapter 1 Installing Windows
9. You can use the default setting for Probe interval and Probe maximum retries. If you change these
values, select a value from each drop-down list, click the target probe (Probe Target xx), and then click
[Edit Target IP Address…].
Tips
• The setting range of Probe interval (link packet transmission interval) is 1 to 60
(units: seconds).
• The setting range of Probe maximum retries (link packet retry count) is 1 to 10
(times).
• Switching a path upon detection of a communication path error by LiveLink takes
(Probe maximum retries + 1) x Probe interval (seconds) at maximum.
If an optional LAN board detects that a link is down, failover occurs immediately
after the link goes down. It takes the time specified for Probe interval (seconds)
to recover from the link going down.
10. In the Target xx text box, enter the IP address of the alive monitoring server, and then click [OK].
Note
• Target xx must be the same broadcast domain as that specified for the data
communication IP and LiveLink communication IP (described in step 13). Specify
an IP address that exists on the network and with which communication is
possible.
• If communication with the IP address specified in Target xx is not possible, the
team will also be unable to communicate. It is therefore recommended that you
specify multiple IP addresses using Probe Target. Up to four IP addresses can
be specified.
Comentarios a estos manuales