NEC Express Server Express5800 Series EXPRESSSCOPE Engine 3 User’s Guide 1. Overview 2. Configuring the Host System 3. Configuring a Manag
subnet mask of your management LAN. If DHCP has been used, an automatically obtained subnet mask IP address will appear. (Default setting is 255.25
use, offer to sell, sell, import, and otherwise transfer the Work, where such license applies only to those patent claims licensable
Contributor provides its Contributions) on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or
1. “Digital Font Program” shall mean a computer program containing, or used to render or display fonts. 2. “Licensed Program” shall mean a Dig
6. The Recipient may reproduce the Licensed Program as is without modification and transfer such copies, publicly transmit or otherwise redistrib
- 104- OF ANY RIGHTS GRANTED HEREUNDER, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 4. The Licensor is under no obligation to respond to
EXPRESSSCOPE Engine 3 User’s Guide ©NEC Corporation 2011-2012 - 105-
- 11- The BMC Initialization also deletes the settings for ESMPRO/ ServerManager(a software application bundled for remote management). Be sure to
3. Configuring a Management PC This chapter describes the settings necessary for the remote management PC that will be connected to the host system.
Notice If the management PC runs Windows XP, remote media function may not work. You need to apply the latest Service Pack.
- 14- 4. Networking TCP/IP PORTS The BMC uses the TCP/IP ports listed below. If you use the BMC in a firewall environment, you need to allocate the
5. Using Remote Management OVERVIEW The BMC Web Server function allows you to control the host system’s power and KVM from a remote console via a Web
If you use Internet Explorer 7(or 8), the following page is displayed and HTTPS connection is blocked. In this case, select "Continue to this
LOGIN AND LOGOUT Login When the login page appears, input the user name and password, and then click [Login]. 1. The display language can b
- 18- Logout Click “Logout” in the upper right corner of the window. When a confirmation dialog appears, click [OK] to log out. After you log o
SERVER PANEL The server panel is displayed under a browser after log in. The server panel has following functions. 7 6 5 4 3 2 1 1. The virtua
TRADEMARKS AND PATENTS EXPRESSSCOPE is registered trademarks of NEC Corporation. EXPRESSBUILDER and ESMPRO are registered trademarks of NEC Corporat
SYSTEM A 4 3 1 2 C B A. The system tab. BMC supported functions are displayed. B. The menu that can be selected in the system tab is displa
REMOTE ACCESS B A C 1 2 3 4 A. The remote access tab. BMC supported functions are displayed. B. The menu that can be selected in the remote ac
- 22- The host system detects remote media as following devices: • AMI Remote FD • AMI Remote CD/DVD • AMI Remote USB Mem The access lamp come
CONFIGURATION C 1 2 3 4 5 6 7 8 A B A. The configuration tab. BMC supported functions are displayed. B. The menu that can be selected in
Power consumption and the throttling situation are displayed. Set to manage the electric power control. 6 Miscellaneous Set to manage from SEL, the
Group Domain Blank Blank Privilege Administrator User LDAP Authentication Disable Disable IP address 0.0.0.0 Blank Port 389 or 639 389 Sea
Port (No Encryption) 5120 5120 Port (Encryption) 5124 5124 Aggressive Mode(*1) Disable No change Power Threshold(Pa) Max Power Consumption No c
- 27- Example of an E-mail alert: Following contents are sent as E-mail alert. Virtual LCD Message: System Rear FAN4 Lower Non-Critical
UPDATE 1 2 B A C A. The update tab. BMC supported functions are displayed. B. The menu that can be selected in the update tab is displayed C. In
6. Command Line Interface OVERVIEW With the BMC Command Line Interface, you can control the host system from a remote SSH client. The BMC supports
Table of Contents Trademarks and Patents...
LOGIN AND LOGOUT Login Enter your user name and password at login prompt. A command prompt will be displayed after login. Also you can login by using
BASIC COMMANDS This section describes basic commands to use them as the command line interface. These basic commands manage the host system by using
help Syntax: help [<options>] [<help topics>] Description: A basic command, <command>, can be specified for the <help topics>
The show command is used to display information about the target specified by the <target> argument. The command displays the target specified
- 34- version Syntax: version [<options>] Description: The version command is used to display the version of the command line protocol specifi
REMOTE CONTROL You can perform remote control of the host system at the command prompt. Notice Performing remote control when the operating system i
Remote Console To start a character-based remote console, enter the following command at the command prompt. start /admin1/system1/textredirectsvc1
- 37- To stop the character-based remote console using by other user forcibly, enter the following command at the command prompt. set /admin1/system
UID Switch Control You can turn on/off the UID (Unit ID) LED on the host system by the virtual UID switch through the command line interface. This f
• The UID LED will blink (flash) when it is controlled by Chassis Identify function of management software such as ESMPRO/ ServerManager. The UID
State Acquisition ...6
SYSTEM EVENT LOG You can display system event log and modify setting of the system event log through the command line interface. Viewing system even
Setting of system event log To move the current default target to /admin1/system1/log1, enter the following command at the command prompt. cd /admin1
ACCESS LOG You can display, clear, and set the access log for the management LAN. The user must have an account as administrator for clearing and s
You can display only access log that corresponded to the specified from following condition. • timestamp Specify the date by the following format: M
Access log might not be correctly displayed with timestamp condition about the log of recorded from AC ON to DC ON on host system. Clearing acc
- 45- means that the access log is disabled. This is the dynamic setting. • oemnec_httplog_enable This specifies whether access log for login/logou
USER SETTINGS This section describes how to confirm and modify the user account through the command line interface. To move the current default targe
NETWORK SETTINGS This section describes how to confirm and modify the network setting for management LAN through the command line interface. To move
The properties which the access limitation target contains are as follows: • oemnec_allowedaccessips This specifies the IP addresses that permit acc
Followings describe how to confirm and modify the DHCP setting for management LAN through the command line interface. To move the current default tar
SYMBOLS The following symbols are used throughout this manual. Notice Items to be observed or points to be noted when using this product. Items to
• AccessInfo This specifies the IP address of the default gateway for the management LAN. This property is read-only. Followings describe how to c
set <Property>=<New value> The properties which the HTTP service target contains are as follows: • EnabledState This specifies whether
- 52- Enter the following command if you would like to modify a property of the SSH service target. set <Property>=<New value> The prop
POWER CONSUMPTION CONTROL You can control the power consumption of the host system through the command line interface. The user must have an account
• oemnec_BootPerformanceOptimized This specifies whether Performance Optimized mode is enabled. This is the dynamic setting. This property is not di
- 55- This specifies the value of the power consumption starting he power consumption control. This is the dynamic setting. This property is not dis
CONFIRMING SYSTEM INFORMATION This section describes how to confirm the system information (product, BIOS/BMC firmware revision, MAC address of Syste
Confirming System BIOS revision You can confirm the System BIOS revision through the command line interface by entering following the basic command a
For example, enter the following command when you would like to confirm the information of CPU1. show cpu1 The example of displaying information in
Confirming Memory Information To move the current default target to /admin1/system1, enter the following command at the command prompt. cd /admin1/sy
PREFACE The EXPRESSSCOPE Engine 3 enables you to monitor the operating status of the host system (power supplies, fans, temperature and so forth), to
SPECIAL EXTENDED COMMANDS This section describes the special extended command which can do state acquisition (powerstate, lampstate) and interrupt ge
- 61- Status LED state acquisition Enter the following command at the command prompt: lampstate -statuslamp One of the following responses is retur
Interrupt Generation for OS Dump You can execute OS dump by entering following command at the command prompt. nmidump /admin1/system1 Notice The use
7. WS-Management (Web Service for Management) OVERVIEW With the WS-Management Protocol, you can control the host system and check the sensor of hos
Power ON Create the file input-RequestPowerStateChange2.xml and enter the following command, if you use WinRM. winrm invoke RequestPowerStateChange h
- 65- D.32+SystemCreationClassName=Host_ComputerSystem -r:https://IP_ADDRESS/wsman -username:USERNAME -password:PASSWORD -auth:basic -encoding:utf-8
OS Shutdown Create the file input-RequestPowerStateChange8.xml and enter the following command, if you use WinRM. winrm invoke RequestPowerStateChang
- 67- System Reset Create the file input-RequestPowerStateChange10.xml and enter the following command, if you use WinRM. winrm invoke RequestPowerS
Interrupt Generation for OS Dump Create the file input-RequestPowerStateChange11.xml and enter the following command, if you use WinRM. winrm invoke
SENSOR INFORMATION You can get sensor information either by enumeration of all sensors or by retrieving specified sensor. Enumeration of All Sensor
1. Overview The host system comes standard with the BMC (system management LSI) and a management LAN port dedicated to the BMC. By connecting the ma
- 70- 8. Troubleshooting ERROR MESSAGES Abnormality occurs while using remote management, and the error dialog might be displayed in management PC
License Notes This product includes open source software programs described below. GNU General Public License • Busybox • Linux Kernel • U-Boot •
software. If the software is modified by someone else and passed on, we want its recipients to know that what they have is not the original, so th
c) If the modified program normally reads commands interactively when run, you must cause it, when started running for such i
anything that is normally distributed (in either source or binary form) with the major components (compiler, kernel, and so on) of the operating syst
implemented by public license practices. Many people have made generous contributions to the wide range of software distributed through that syste
PROGRAMS), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. END OF TERMS AND CONDITIONS
This General Public License does not permit incorporating your program into proprietary programs. If your program is a subroutine library, you may
We protect your rights with a two-step method: (1) we copyright the library, and (2) we offer you this license, which gives you legal permission
linked with the Library has the freedom and the wherewithal to run that program using a modified version of the Library. The precise terms and c
2. Configuring the Host System This chapter describes the settings necessary to configure the BMC in the host system. DEFAULT NETWORK SETTINGS The B
distribute such modifications or work under the terms of Section 1 above, provided that you also meet all of these conditions: a) The modifi
subsequent copies and derivative works made from that copy. This option is useful when you wish to copy part of the code of the Library into a p
this License. You must supply a copy of this License. If the work during execution displays copyright notices, you must include the copyright n
permitted, and provided that you do these two things: a) Accompany the combined library with a copy of the same work based on the Li
generous contributions to the wide range of software distributed through that system in reliance on consistent application of that system; it is up t
FAILURE OF THE LIBRARY TO OPERATE WITH ANY OTHER SOFTWARE), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
LICENSE ISSUES ============== The OpenSSL toolkit stays under a dual license, i.e. both the conditions of the OpenSSL License and the o
* OF THE POSSIBILITY OF SUCH DAMAGE. * ==================================================================== * * This product includes cryptogra
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
* Copyright (c) 1995 Tatu Ylonen <[email protected]>, Espoo, Finland * All rights reserved * * As far as I
MANAGEMENT LAN SETTINGS You can configure basic setting of management LAN settings of BMC for remote management using Web server function and command
* Copyright (c) 1998 CORE SDI S.A., Buenos Aires, Argentina. * * All rights reserved. Redistribution and use in source and binary
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE * ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTO
a) md5crypt.c, md5crypt.h * "THE BEER-WARE LICENSE" (Revision 42): * <[email protected]> wrote this file. As long as yo
Some code is licensed under a MIT-style license to the following copyright holders: Free Software Foundation, Inc. * Permission i
All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted only as authorized by the OpenLDA
* copies. * * This software is provided "as is" and without any expressed or implied * warranties, including, without limitation, the impli
SQLite SQLite is in the Public Domain All of the deliverable code in SQLite has been dedicated to the public domain by the authors. All code auth
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* may be used to endorse or promote products derived from this software * without specific prior written permission. * * THIS SOFTWARE IS
"Licensor" shall mean the copyright owner or entity authorized by the copyright owner that is granting the License. "
Comentarios a estos manuales