Vista de pagina 142
Troubleshooting 8-19
Problems with RAID System and RAID Controller
Fail to install the OS:
Did you create virtual disk?
Create virtual disks by using WebBIOS.
Fail to start the OS:
Are hard disk drives properly installed?
Install them properly.
If the same error persists, the hard disk drive or RAID Controller may be faulty.
Contact your service representative.
A hard disk drive fails:
Contact your service representative.
Rebuild fails:
Is the capacity of the hard disk drive to be rebuilt sufficient?
The hard disk drive to be rebuilt should have the same capacity of the failed had
disk drive.
Is RAID0 configured for virtual disk?
RAID0 has no data redundancy, therefore, Rebuild is disabled in the RAID0
configuration. Replace the failed hard disk drive, then create the virtual disk again.
Check Consistency fails:
Is virtual disk "Degraded"?
Replace the failed hard disk drive with new one, then perform Rebuild.
Is RAID0 configured for virtual disk?
RAID0 has no data redundancy, therefore, Check Consistency is disabled in the
RAID0 configuration.
Cannot set Write-Back for cache mode:
The current cache mode of RAID controller is displayed on [Virtual Disks] -
[Properties] - [Policies] - "Write". If additional battery is faulty or insufficiently
charged, the cache mode is changed to "WThru (Write Through)" even if you
specify "WBack (Write Back)". See Chapter 4 for details.