Troubleshooting 8-19
Problems with RAID System and RAID Controller
Fail to install the OS:
Did you create virtual disk?
→ Create virtual disks by using WebBIOS.
Fail to start the OS:
Are hard disk drives properly installed?
→ Install them properly.
If the same error persists, the hard disk drive or RAID Controller may be faulty.
Contact your service representative.
A hard disk drive fails:
→ Contact your service representative.
Rebuild fails:
Is the capacity of the hard disk drive to be rebuilt sufficient?
→ The hard disk drive to be rebuilt should have the same capacity of the failed had
disk drive.
Is RAID0 configured for virtual disk?
→ RAID0 has no data redundancy, therefore, Rebuild is disabled in the RAID0
configuration. Replace the failed hard disk drive, then create the virtual disk again.
Check Consistency fails:
Is virtual disk "Degraded"?
→ Replace the failed hard disk drive with new one, then perform Rebuild.
Is RAID0 configured for virtual disk?
→ RAID0 has no data redundancy, therefore, Check Consistency is disabled in the
RAID0 configuration.
Cannot set Write-Back for cache mode:
→ The current cache mode of RAID controller is displayed on [Virtual Disks] -
[Properties] - [Policies] - "Write". If additional battery is faulty or insufficiently
charged, the cache mode is changed to "WThru (Write Through)" even if you
specify "WBack (Write Back)". See Chapter 4 for details.