Troubleshooting 8-7
Virtual LCD indications when STATUS lamp is flashing in red
On-screen message Description Action
MEZ1 Power Fault An error was detected in power
circuit of mezzanine card installed in
Type 1 slot of Storage and I/O Blade.
MEZ2 Power Fault
An error was detected in power
circuit of mezzanine card installed in
Type 2 slot of Storage and I/O Blade.
Check installation status of
mezzanine card.
If the same error persists, contact
your service representative.
AmbientTempAlm09 A high temperature error was
detected in Storage and I/O Blade.
Check if fans in Blade Enclosure
work normally.
Refer to the User’s Guide of the
Blade Enclosure to make sure that
the sufficient number of fans are
installed in correct locations.
Check if the fans and Storage and
I/O Blade are installed in correct
locations.
Check if the ambient temperature
of installation location satisfies the
operation guarantee condition.
If the same error persists, contact
your service representative.
AmbientTempAlm02 A low temperature error was
detected in Storage and I/O Blade.
Check if the ambient temperature
of installation location satisfies the
operation guarantee condition.
If the same error persists, contact
your service representative.
BB +1.0v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +0.9vs Alm XX
BB +1.0vs Alm XX
BB +1.8vs Alm XX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Battery Alm XX
A voltage alarm was detected in
Storage and I/O Blade.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
Contact your service
representative.