Color Sensor
Problem: Software is unable to detect the X-Rite ColorMunki
Solution: If the X-Rite ColorMunki software is installed, it will prevent NEC Display Wall Calibrator from accessing the
device even if the main ColorMunki application is not currently running.
If the ColorMunki software prior to version 1.1.0 is being used
NEC Display Wall Calibrator will detect if the ColorMunki software is running and give the option of closing
it automatically.
To use the ColorMunki software again after NEC Display Wall Calibrator has closed it, the colormunki.exe
application must be run from the Startup menu in Windows.
If the ColorMunki software version 1.1.0 or newer is being used:
The ColorMunki Service in the Windows Control Panel > “X-Rite Device Services” must be turned off to
allow NEC Display Wall Calibrator to access the device.
To use the ColorMunki software again, the ColorMunki Service must be turned back on.
Problem: When calibrating or measuring a display, the software becomes stuck with the message “Detecting sensor
on display”.
Solution: The software detects that the sensor is positioned on the correct display by ashing alternate red and green
patterns on the display and taking measurements with the color sensor. If valid color measurements are not detected
then the calibration or measurement will not proceed. If the color sensor is damaged or has become very inaccurate it
may not be able to detect the colors correctly. It may be necessary to replace the color sensor.
Problem: DataColor Spyder 3 color sensor is not detected (Windows only).
Solution: The device drivers may not be installed. Open the Windows device manager and locate the Spyder 3 de-
vice. Select Update Drivers and provide the location of the drivers. The driver les are copied during installation to the
following folders:
On 32 bit Windows:
C:\Program Files\NEC Display Solutions\NEC Display Wall Calibrator\Drivers\Spyder3
On 64 bit Windows:
C:\Program Files (x86)\NEC Display Solutions\NEC Display Wall Calibrator\Drivers\Spyder3
If the drivers are not installed in this location, reinstall NEC Display Wall Calibrator and make sure the option to install
the Spyder 3 drivers is selected.