25 | NEC DISPLAY WALL CALIBRATOR - USER’S GUIDE
Example: Direct Multi IP LAN
Supported display connection congurations
LAN1 LAN2
RS-232C
RS-232C IN, LAN 1 and LAN2
RS-232C
IN
RS-232C
OUT
LAN
RS-232C IN, OUT, and LAN
In this example, the host PC and each display are individually connected to the LAN via hub. Each display has a unique
IP address.
Important: Models with only one LAN connection must be congured to use LAN as the EXTERNAL CONTROL on the OSD.
Models with two LAN connections do not have this setting.
The software is congured with the IP address and MONITOR ID of each display.
The Monitor ID of each display does not need to be unique since the displays are not daisy-chained, however the ID set
on the OSD must match that set in the software.
LAN
LAN
LAN
LAN
LAN
ID 1
LAN
IP 192.168.0.1
Display 1
ID 1
LAN
IP 192.168.0.2
Display 2
ID 1
LAN
IP 192.168.0.3
Display 3
ID 1
LAN
IP 192.168.0.4
Display 4
PC
IP 192.168.0.200
LAN HUB
The following image shows how this layout looks in the Summary window when congured.