NEC Express5800/R120f-1M Guía de instalación Pagina 218

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 344
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 217
5. Setting Up Windows Server 2008 R2
Express5800/R120f-1M, R120f-2M Installation Guide (Windows)
218
Chapter 1 Installing Windows
8. When configuring LiveLink, select Yes, click Next, and then go to step 9.
When configuring LiveLink is unnecessary, select No, click Next, and then go to step 15.
9. You can use the default setting for Probe interval and Probe maximum retries. If you change these
values, select a value from each drop-down list, click the target probe (Probe Target xx), and then click
Edit Target IP Address.
Tips
The setting range of Probe interval (link packet transmission interval) is 1 to 60
(units: seconds).
The setting range of Probe maximum retries (link packet retry count) is 1 to 10
(times).
Switching a path upon detection of a communication path error by LiveLink
takes (Probe maximum retries + 1) x Probe interval (seconds) at maximum.
If a link down is detected, failover occurs immediately after the link goes down. It
takes the time specified for Probe interval (seconds) to recover from the link
going down.
When using Tagged VLAN, input the VLAN ID for Probe VLAN ID.
Vista de pagina 217
1 2 ... 213 214 215 216 217 218 219 220 221 222 223 ... 343 344

Comentarios a estos manuales

Sin comentarios