Troubleshooting 7-5
STATUS LED
Indication
Color State
Suspected
module
Explanation Procedure
Cor0 +5.0vAlm
09
Amber Lit PCI module #1 Fatal 5-V power voltage alarm
(upper limit)
Cor0 +5.0vsAlm
00
Amber Blink PCI module #1 5-V power voltage alarm
(lower limit)
Cor0 +5.0vsAlm
02
Amber Lit PCI module #1 Fatal 5-V power voltage alarm
(lower limit)
Cor0 +5.0vsAlm
07
Amber Blink PCI module #1 5-V power voltage alarm
(upper limit)
Cor0 +5.0vsAlm
09
Amber Lit PCI module #1 Fatal 5-V power voltage alarm
(upper limit)
Cor0 -12vAlm 00
Amber Blink PCI module #1 -12-V power voltage alarm
(lower limit)
Cor0 -12vAlm 02
Amber Lit PCI module #1 Fatal -12-V power voltage
alarm (lower limit)
Cor0 -12vAlm 07
Amber Blink PCI module #1 -12-V power voltage alarm
(upper limit)
Contact your sales agent.
Cor0 -12vAlm 09
Amber Lit PCI module #1 Fatal -12-V power voltage
alarm (upper limit)
Cor0 Bus PERR
01
Green Blink PCI module #1 PCI bus parity error
Cor0 Bus SERR
01
Green Blink PCI module #1 Fatal PCI bus error
Cor0 CLK Alm 00
Amber Blink CLOCK board Clock alarm (lower limit)
Cor0 CLK Alm 02
Amber Lit CLOCK board Fatal Clock alarm (lower
limit)
Cor0 CLK Alm 07
Amber Blink CLOCK board Clock alarm (upper limit)
Cor0 CLK Alm 09
Amber Lit CLOCK board Fatal Clock alarm (upper
limit)
Contact your sales agent.
Cor0 FAN Alm 01
Amber Blink PCI module #1 Cooling fan1 alarm
Cor0 FAN Alm 02
Amber Blink PCI module #1 Cooling fan2 alarm
Cor0 FAN Alm 03
Amber Blink PCI module #1 Cooling fan3 alarm
Cor0 FAN Alm 04
Amber Blink PCI module #1 Cooling fan4 alarm
Cor0 FAN Alm 05
Amber Blink PCI module #1 Cooling fan5 alarm
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
Cor0 offline
Green Blink PCI module #1 PCI module logically isolated Start the PCI module by ft
sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.
Cor0 removed
Green Blink PCI module #1 PCI module detached Dismount and remount the
PCI module. If not solved
by the above, contact your
sales agent.
Cor0 Temp Alm
00
Amber Blink PCI module #1 Temperature alarm (lower
limit)
Cor0 Temp Alm
02
Amber Lit PCI module #1 Fatal temperature alarm
(lower limit)
Cor0 Temp Alm
07
Amber Blink PCI module #1 Temperature alarm (upper
limit)
Cor0 Temp Alm
09
Amber Lit PCI module #1 Fatal temperature alarm
(upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.