CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN-PRI Programming
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 71
When providing Tandem Connection (ODT/DTI to ISDN, ISDN to ODT/DTI), do the following
programming:
DESCRIPTION DATA
Specify the combination of trunk routes
allowing the tandem connection.
(1)
(2)
Y=0
XX ZZ
XX: 00-63: Incoming Trunk Route
ZZ: 00-63: Outgoing Trunk Route
0 : Allowed
1: Restricted
Specify the timing start when making an
ISDN call from a station (PB/DP
telephone/D
term
) or Attendant Console for
the Tandem Connection.
(1)
(2)
Y=0
57
03-14: 3 sec.-14 sec.
If no data is set, the timing start is not
effective.
NOTE 1: By using CM41 Y=0>57, an ISDN call is available even if “#” is not dialed.
NOTE 2: CM41 Y=0>57 is effective for dialing a called number. When dialing a called party
subaddress, this command is not effective.