Page 104 ND-70919 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN Terminal Data Programming
Point-to-Point Connection
DESCRIPTION DATA
Assign the point to point connection as the
Layer 2 data link.
(1)
(2)
YY=01
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
0: Point to Point Connection
NOTE: When Point-to-Point Connection is selected, the PBX will address the BRI Terminal
with channel select (B1/B2) message. Some BRI Terminals cannot answer the call
with this type of signaling. Some of the BRI Terminals require a Calling Party
Number sent from the PBX. In this case, use Point-to-Multipoint for CMAC YY=01
and CM1B to assign extension number for the BRI Terminal.
Assign the TEI Manual Assignment.
(1)
(2)
YY=02
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
0: TEI Manual Assignment
Assign the Extended Passive Bus.
(1)
(2)
YY=03
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
0: Extended Passive Bus
Assign the always activated as the method
of Layer 1 activation.
(1)
(2)
YY=04
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
0: Always activated
MDF
ISDN Terminal/TA
Max. 1965 ft. (600 m)
ILC
PBX
CMAC
START
END
INITIAL
INITIAL
INITIAL
INITIAL