NEAX2000 IVS
2
ISDN System Manual
Page 98 ND-70919 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN Feature Programming
Centrex SHF Over ISDN
[N.Z. Only]
To send hooking signal from a D
term
to a main PBX via ISDN, do the following programming:
DESCRIPTION DATA
Provide the voice channel trunk route for
the main PBX with the Centrex function.
(1)
(2)
YY=86
00-63: B channel Trunk Route No.
0: To provide
Assign the SHF Key on the D
term
.
(1)
(2)
YY=00
My Line No. + + Key No.
F1009: SHF (Hooking Signal sent to
outside)
D
term
D
term
DLC
DTI
DTI DLC
DCH
DCH
PBX
MAIN PBX
ISDN
ISDN
START
CM35
END
CM90
,