CHAPTER 4 CIRCUIT CARD INFORMATION
PN-2ILCA (ILC)
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 187
Lamp Indications
LAMP
NAME
COLOR FUNCTION
ACT1 Green No. 1
Circuit
ON: Normally operating
OFF: Not operating
PAL1 Red ON: Line is short-circuiting.
OFF: Normally operating
LPB1 Red OFF: Not used
B21 Green ON: B2 channel is in use.
OFF: B2 channel is idle.
B11 Green ON: B1 channel is in use.
OFF: B1 channel is idle.
ACT0 Green No. 0
Circuit
ON: Normally operating
OFF: Not operating
PAL0 Red ON: Line is short-circuiting.
OFF: Normally operating
LPB0 Red OFF: Not used
B20 Green ON: B2 channel is in use.
OFF: B2 channel is idle.
B10 Green ON: B1 channel is in use.
OFF: B1 channel is idle.