Next enter a temporary IP address for the PC, such as
192.168.0.255, and a subnet mask of 255.255.255.0. Click OK
and close the Network Settings.
Next open a web browser and go to the URL of the display’s web server by entering:
http://192.168.0.10
This should display the display’s MONITOR NETWORK SETTINGS page.
If this page can not be reached:
Conrm that the display is powered on and connected to the PC either directly or via a HUB.
Conrm that the IP address assigned to the display is at the default value, by performing a LAN RESET from the
OSD on the display.
Conrm that the EXTERNAL CONTROL setting on the OSD is set to LAN.
Try refreshing the web page in the browser. It may take several refreshes before the display can be found.
Check if any rewall software or settings on the PC could be preventing access to the display’s IP address.
Try resetting the power to the display.
Once the web page has appeared, the display’s IP address and subnet mask can be entered and updated in the display.
It is highly recommended to assign each display a static IP address so that the IP address will not be reassigned to
another device if the network is reset.
Note: Once the IP address is updated, the display will no longer be accessible from the current IP address.
Next restore the original network settings on the PC.