12 | NEC PD COMMS TOOL - USER’S GUIDE
Main Window - Function List
Controls - By OpCode panel
The Controls - By OpCode panel provides access for Get (reading) and Set (writing) control settings. Each control has
an Op Code number assigned. See the protocol specication document for your model of display for a list of supported
controls and Op Codes.
Controls can accessed either by selecting the Op Code by name from the Op Code Control Name list, or by entering
the hexadecimal Op Code value directly into the Op Code setting. The Op Code Control Name list can be ordered
alphabetically, or by functional category by selecting List by category.
Clicking Get will attempt to read the current value of the selected Op Code control. The monitor will reply with the status
of if the Op Code is supported, the current value, and the maximum possible value.
The value of the Op Code returned from the display will be shown. For some controls, such as Input, where each value
has discrete setting, the value will be shown in the Value Setting list. For other controls such as Brightness which have
a continuous range, the value will be shown on the Value Setting slider control.
The setting value for the Op Code control can be updated in the monitor by either:
• Editing the Value setting, and clicking Set.
• Selecting an item from the Value Setting list.
• Adjusting the Value Setting slider control.
Note: When completed making adjustments, it is good practice to click the Save All Settings button which will force the monitor
to save the changes.