NEC PD Comms Tool Guía de usuario Pagina 47

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 46
47 | NEC PD COMMS TOOL - USER’S GUIDE
DISPLAYPORT
HDMI
PICTUREMODE xxx - sets the Picture Mode to xxxx. Either a numerical value or a name can be specied.
Valid Picture Mode names are as follows:
LASTSETTING
SRGB
HIBRIGHT
STANDARD
CINEMA
ISF-DAY
ISF-NIGHT
AMBIENT-1
AMBIENT-2
ONTIME CLEAR - clears (unsets) the Power On Time for the schedule
ONTIME hh:mm - sets the Power On Time to hh hours and mm minutes. Hours should be specied in 24 hour
format.
OFFTIME CLEAR - clears (unsets) the Power Off Time for the schedule
OFFTIME hh:mm - sets the Power Off Time to hh hours and mm minutes. Hours should be specied in 24 hour
format.
Example 1
SCHEDULE 1 DISABLE
This disables the schedule #1
Example 2
SCHEDULE 2 ENABLE EVERYDAY SET INPUT HDMI ONTIME 8:30 OFFTIME 17:00
This enables the schedule #2, sets the Every Day setting, Selects the HDMI input, sets the Power On Time to 8:30AM,
and sets the Power Off Time to 5:00PM.
Example 3
SCHEDULE 3 ENABLE EVERYDAY CLEAR EVERYWEEK SET MONDAY CLEAR TUESDAY CLEAR WEDNESDAY CLEAR
THURSDAY CLEAR FRIDAY CLEAR SATURDAY SET SUNDAY SET
This enables the schedule #3, clears the Every Day setting, as well as Monday-Friday, but sets Saturday and Sunday,
as well as Every Week.
Note: To reset all schedules, the “Menu Tree Reset” OPCODE with the value “Reset Schedule” can be used, followed
by a delay to allow the display time to process the reset command. e.g. add the following lines to the script:
SETOPCODE "Menu Tree Reset" TO "Reset Schedule"
WAIT 3000