♦When Performing Duplex System Management
To perform duplex system management, install NEC ESMPRO Agent on a local disk on both the operating and standby
servers. The installation procedure for NEC ESMPRO Agent is same as a normal installation, except that it should be
installed on two servers.
♦Restart after HW trouble occurs
When abnormality of HW is detected, OS is shutdown.
When the morrow is started, it is likely to shutdown when OS is restart without action/recovering trouble after it
shutdown. Restart OS after action/recovering trouble.
♦Shutdown monitoring
When performing shutdown monitoring, all shutdown processes are to be monitored. If there is an application that
performs shutdown without rebooting OS or turning off the power, set the timeout value longer or disable the monitoring
function.
♦Monitoring LAN via IEEE1394 interface
If you connect an IEEE1394 network adapter and an IEEE1394 network adapter on another equipment, NEC ESMPRO
Agent could not monitor LAN activity.
IEEE1394 connection
Server Server
♦Memory leak
Memory leak occurs intermittently irregularly on Windows Vista RTM, Windows Vista SP1, or Windows Server 2008.
The detailed information is described on Microsoft Product Support Services.
Check the contents.
[Article ID: 955515]
http://support.microsoft.com/kb/955515/en-us
Execute the above hotfix or the Service Pack 2.
NEC recommends the Service Pack 2.
As for this phenomenon, [About Alert Manager] occurs in the case of 4.10 or later.
The confirmation procedure of [About Alert Manager] is as follows.
1 Go to [Start]-[Control Panel] and select [NEC ESMPRO Agent].
2 Click [General]-[Report Setting...].
Displays Alert Manager.
3 Click the "Help" - "About Alert Manager" menu on Alert Manager.
4 Confirm version of "Alert Manager".
Example) Alert Manager Ver. 4.10
33