Changing setting of storage monitoring
The following setting will not take effect until one (old) monitoring interval cycle of each monitoring service passes after
changes are made to setting.
sampling interval (Polling Frequency tab of storage setting) reset (Reset tab of storage setting and Reset button on
Hard Disk General view in [Information of server state/constitution] of NEC ESMPRO Manager) hard disk pre-failure
prediction mode (HD Pre-failure tab of storage setting) thresholds of free block monitoring (Free Space tab of storage
setting and threshold button on File System General view in [Information of server state/constitution] of NEC ESMPRO
Manager).
Changing mode of hard disk pre-failure prediction
Turning on/off the mode of hard disk pre-failure prediction, all hard disks work in the same mode in either case. You can
not set the mode of each hard disk individually.
Storage Devices other than SCSI/IDE Device
NEC ESMPRO Agent does not monitor storage devices other than SCSI/IDE devices (e.g., an USB device).
Display of the [Information of server state/constitution] of NEC ESMPRO Manager
when a Hard Disk Drive is connected
In the case of using the LSI RAID system, even if you connect a Hard Disk Drive to the RAID Contoller, the connected
Hard Disk Drive may not be displayed of the [Information of server state/constitution] of NEC ESMPRO Manager.
In such a case, recognize the Hard Disk Drive by the RAID system configuration.
Network drive is not displayed of the [Information of server state/constitution] of
NEC ESMPRO Manager
On Windows XP or the OS released after it, the drive connected to network is not displayed under the file system tree
in the [Information of server state/constitution] of NEC ESMPRO Manager.
Information displayed in "Resource" of SCSI controller
In the following cases, check the information of resource using "Device Manager" and "System Information
(winmsd.exe)" of OS.
- x64 Edition OSs
Incorrect information may appear in the [Resource] window displayed from [SCSI Controller] of [Information of
server state/constitution] of NEC ESMPRO Manager.
- Windows Vista or later
I/O port information does not appear in the [Resource] window displayed from [SCSI Controller] of [Information of
server state/constitution] of NEC ESMPRO Manager.