♦Display of the [Information of server state/constitution] of NEC ESMPRO Manager
when the RAID System is changed
When a Physical Device and a Logical Device are added or are deleted when immediately after the installation of NEC
ESMPRO Agent and the RAID System are maintaining it, it takes time of a few minutes until information is displayed of
the [Information of server state/constitution] of NEC ESMPRO Manager.
♦SATA Optical disk drive
In the case of using the LSI Embedded MegaRAID, infomation of SATA Optical disk drive does not displayed of the
[Information of server state/constitution] of NEC ESMPRO Manager.
8.3 I/O device
♦Floppy Disk Drive Information
If you add or delete floppy disk drive connected with USB while the OS is running, the drive information under the [I/O
Device] of the [Information of server state/constitution] of NEC ESMPRO Manager will be updated at the next system
startup.
♦Serial Port
For the models supporting serial ports, note the following.
NEC ESMPRO Agent has multiple features that use serial ports.
When using these features, the ports may become insufficient.
The serial ports available for each feature are as follows.
UPS : COM1-10
APCU : COM1-2
ALIVE Maintenance* : COM1-9
*Alive Maintenance uses Remote Access Service.
The available serial ports when using Remote Access Service for Manager Report (TCP/IP Out-of-Band) are as
follows.
Manager Report: COM1-10
Among those above, only the following combination can share the serial ports.
- Alive Maintenance + Remote Access Service used by a user
When one of the features uses the line, the other feature cannot be used.
Manager Report (TCP /IP Out-of-Band),
which uses Remote Access Service, may be unable to
notify failure information when sharing other serial port. Ensure not to share serial ports.