NEC Express5800/120Bb-6 Guía de usuario Pagina 134

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 146
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 133
114
4-2 Manual Rebuild
Described below is the rebuild procedure when one of the HDD fails in a RAID1 virtual disk configured with
two HDDs.Replace the failed HDD with a new one after turning off the power of the server. The Auto Rebuild
feature is disabled for non-hot-swap replacement. Use the Manual Rebuild feature to recover the virtual disk
as described below:
1. Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF GOOD" in the right frame
of the top menu.
2
3
2. Make sure that the HDD that has been installed in slot 1 is missing.
3. Select "PD2" (newly connected HDD) in [Physical Drives].
The properties for the physical drive are displayed.
4. Select "Make Global HSP" from the lower right of the screen, and then click [Go] at the lower center
of the screen.
Vista de pagina 133