NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
37
component if “ACPI Redirection” exists on the “Console Redirection”.
4.3.2.4 CUI Remote Console after Windows Boot
-- The remote console via LAN cannot be used for SAC if the managed component does not support SOL.
-- To execute the CUI remote console function of the SAC screen after Windows boot, select “Server” ->
“Console Redirection” and change “ACPI Redirection” to “Enable” on the BIOS Setup Utility screen of
the managed component. When “ACPI Redirection” is set to “Enable” on the BIOS Setup Utility screen,
the CUI remote console function cannot be executed after POST.
If “ACPI Redirection” does not exist on the “Console Redirection” menu, please confirm that “Console
Redirection after POST” is enabled.
4.3.2.5 CUI Remote Console under Linux
-- The remote console by the redirection function of Linux cannot be used via LAN if the managed
component does not support SOL.
-- To execute the CUI remote console function of the Linux redirection, select “Server” -> “Console
Redirection” and change “ACPI Redirection” to “Disable” on the BIOS Setup Utility screen of the managed
component if “ACPI Redirection” exists on the “Console Redirection”.
-- When you execute a remote console by the redirection function of Linux, following settings are necessary.
(1) Set as following example at the line that begins with “kernel/vmlinuz” in the setting file
(/boot/grub/grub.conf) on Linux:
console=tty0 console=ttyS1,19200n8r
(2) Make a setting like the following example in the setting file (/etc/inittab) on Linux:
S0:2345:respawn:/sbin/agetty –h –L 19200 ttyS1 vt100
(Explanation of the example setting)
“agetty” is to be used in the following conditions:
* Hardware control (RTS/CTS) is enabled. (This setting is an example. Determine whether to
enable/disable it, conforming to the configuration information setting on the managed component.)
* A directly connected local line not requiring carrier detection is assumed.
* Baud rate 19200 bps (This setting is an example. Set the baud rate conforming to the BMC
configuration information setting on the managed component.)
* Serial1 port 2 of the managed component is used.
* The terminal type is vt100.
-- Even if connection with a managed component is of any type (LAN, WAN, or Direct), Linux on the
managed component recognizes that operation through the remote console of the DianaScope Manager is
connection via the serial port. The initial setting on Linux does not permit any super-user (root) to log in
via the serial port. To log in as a super-user, disable the security function for the serial port 2. Be very
careful of operation in this case.
To disable the security function for the serial port 2, add “ttyS1” to the /etc/security file.
-- To display the editor or menu screen on the CUI remote console, set the OS terminal screen to the
80-column, 24-line size.
Comentarios a estos manuales