NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
19
-- Change of the hardware of a default gateway or an alert receiver
In case that there is a gateway between NEC ESMPRO Manager server and a managed component,
re-configure BMC on the managed component after the change the hardware of the gateway. In case that
there is not gateway between an alert receiver and a managed component, re-configure BMC on the
managed component after the change the hardware of the alert receiver. The BMC on the managed
component can know MAC address of the new hardware by setting the BMC configuration.
-- Use of a dialup router or a PPP server
If an alert receiver via modem uses Windows Remote Access Service, please select “Allow any
authentication including clear text” about the encryption on the Windows Remote Access Service
properties.
-- Restrictions on use of the standard serial port 2 (COM2)
The standard serial port 2 (COM2) on a managed component cannot be used for connecting another device
in the following cases because the BMC occupies the serial port 2:
- The managed component compatible with SOL and set enable on following BMC Configuration items:
“Remote control (WAN/Direct)”
“Redirection (LAN)”
“Redirection (WAN/Direct)”
- Connection via modem or Direct connection has been made.
- Direct connection has been set in the BMC configuration information. (Even if the NEC ESMPRO
Manager and managed component are not connected, the BMC occupies the serial port 2 (COM2).)
CHECK:
See “Appendix C. Managed Components Summary” of the “NEC ESMPRO Manager Ver.5
Setup Guide” to confirm whether that your component supports SOL.