4-8 Linux Setup
(2) Make sure that the two BMC Status LEDs of the PCI modules (for Group1/for Group2) are
turned off.
IMPORTANT: While the BMC Status LED is red and blinking, do not
perform (3) and on. Otherwise the BMC firmware may become damaged.
(3) Remove the power cord of the AC inlet A (for Group2).
(4) Check that the POWER switch of the PCI module for Group1 is turned on.
(5) Connect the power cord of the AC inlet A (for Group2).
(6) Make sure that two BMC Status LED for PCI modules (for Group 1/for Group 2) are
turned off.
IMPORTANT: If the BMC Status LED is red and blinking, do not start
installing Linux for NEC Express5800/ft series. Otherwise the setup may not be
done properly.
Preparation is now completed. Start the installation of Linux for NEC Express5800/ft series.