3-20 ESMPRO Agent for Linux
Fatal High Limit > Fatal High Reset > Warning High Limit > Warning High
Reset
The high temperature limit can range from 30°C to 70°C (86°F to 160°F).
Warning high/report - (warning high limit) When the temperature exceeds this
value, a warning alert message is generated and the status of the Agent changes
to warning. The warning high limit must meet the following condition:
Fatal High Limit > Fatal High Reset > Warning High Limit > Warning High
Reset
Warning low/report - (warning low limit) When the temperature falls below
this value, a warning alert message is generated and the status of the Agent
changes to warning. The warning low limit must meet the following condition:
Warning Low Reset > Warning Low Limit > Fatal Low Reset > Fatal Low
Limit
Fatal low/report - (fatal low limit) When the temperature falls below this value,
a fatal alert message is generated and the status of the Agent changes to
abnormal. The fatal low limit must meet the following conditions:
Warning Low Reset > Warning Low Limit > Fatal Low Reset > Fatal Low
Limit
The low temperature limit can range from -10°C to 30°C (15°F to 86°F).