Chapter 6: Advanced Chassis Setup
6-9
6025B-3R
The Series3800/120R-2 (6025B-3R) has a 700 watt redundant power supply con-
sisting of two power modules. Each power supply module has an auto-switching
capability, which enables it to automatically sense and operate at a 100V - 240V
input voltage.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption. The PWR
Fail LED will illuminate and remain on until the failed unit has been replaced. The
power supply units have a hot-swap capability, meaning you can replace the failed
unit without powering down the system.
Removing/Replacing the Power Supply
You do not need to shut down the system to replace a power supply unit. The
backup power supply module will keep the system up and running while you replace
the failed hot-swap unit. Replace with the same model.
1. Removing the power supply
First unplug the power cord from the failed power supply module. Then depress
the locking tab on the power supply module and use the handle to pull it straight
out with the rounded handle.
2. Installing a new power supply
Replace the failed hot-swap unit with another identical power supply unit (p/n
PWS-702A-1R). Simply push the new power supply unit into the power bay until
you hear a click. Secure the locking tab on the unit and fi nish by plugging the AC
power cord back into the unit.