Chapter 6: Advanced Chassis Setup
6-3
6-3 System Fans
Three 8-cm fans provide all the cooling needed for the Series3800/SR120R-2
(6025B-3/6025B-3R). It is very important that the chassis top cover is properly
installed and making a good seal in order for the cooling air to circulate properly
through the chassis and cool the components. See Figure 6-2.
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails,
the remaining fans will ramp up to full speed and the overheat/fan fail LED on the
control panel will ash. Replace any failed fan at your earliest convenience with the
same type and model (the system can continue to run with a failed fan). Remove
the top chassis cover (see instructions in Chapter 2) while the system is still running
to determine which of the fans has failed.
The hot-plug fan will start to function upon connection to its fan header on the
serverboard.
Replacing System Fans
1. Removing a fan
Remove the chassis cover. Press the tabs on the top of the fan housing and remove
the fan in its housing (see Figure 6-2). System power does not need to be shut
down since the fans are all hot-pluggable.
2. Installing a new fan
Replace the failed fan with an identical 8-cm, 12 volt fan (p/n FAN-0070). Position
the new fan at its proper place in the chassis by tting the fan with its housing onto
the fan mounts in the chassis. A "click" can be heard if the fan (in its housing) is
properly installed. If the system power is on, the hot-plug feature will cause the fan
to start immediately upon being connected to its header on the serverboard.